1. The law aims to protect persons, animals, and property against fire and explosion damage.

2. Functions and job titles apply to both genders.

General Provisions

1. Everyone must exercise the necessary caution in the use of heat, light, and other types of energy to prevent fires and explosions. This is especially applicable with fire and open flames, additionally when flammable, environmentally harmful, or health-damaging substances and goods could catch fire, as well as during the operation of machines and devices.

2. When utilizing auxiliary personnel, it must be ensured that they are properly selected and instructed, and that the necessary precautionary measures are taken.

General Provisions

1. Buildings, storage facilities, and other installations, along with operational equipment, must be constructed, operated, and maintained in such a manner that

a) the occurrence of fires and explosions and the spread of flames, heat, and smoke are sufficiently prevented;

b) the safety of individuals is ensured;

c) environmental and health damages as a result of fires are avoided;

d) animals and property are adequately protected;

e) effective fire fighting is made possible.

2. The Government Council shall issue regulations concerning the necessary measures to ensure structural and operational fire protection.

3. The type and scope of measures for buildings are primarily determined by

a) the number and vulnerability of persons present in the building,

b) the purpose and construction type of the building, its location, and accessibility for the fire department,

c) size (floor area and height),

d) fire load, combustibility of materials, and risk of smoke,

e) risk of forming hazardous chemical compounds under heat exposure,

f) risk of corrosion,

g) risk of activation (ignition sources),

h) fire fighting capabilities.

General Provisions

1. Measures for Fire Situations shall be implemented in such a way that legal provisions serving the protection of the environment and health can be complied with. In particular, measures must be planned to prevent the contamination of extinguishing water with pollutants or its uncontrolled drainage.

General Provisions

1. The governing council may declare the technical guidelines of recognized professional associations regarding structural and operational fire protection to be binding, provided they comply with the principle of proportionality and the criteria listed in §§ 3 and 4.

2. The governing council shall publish its decision in the collection of laws and shall also specify where the guidelines can be inspected.

General Provisions

1. The legally prescribed measures are based on the level of fire hazard that can be expected under normal circumstances.

2. Prescribed measures may be replaced by alternatives, provided they are equivalent for the individual object.

3. If the fire hazard in a particular case deviates from the normal to such an extent that the legally prescribed measures appear insufficient or disproportionate, the measures to be taken can be appropriately expanded or reduced.

General Provisions

1. The provisions regarding structural and operational fire protection are directed at owners, occupiers, users, and moreover at all individuals involved in the construction, operation, or maintenance of a building or facility.

2. The owner of the building or facility is responsible for complying with structural fire protection requirements, while the operator is responsible for adhering to operational requirements. These obligations also bind legal successors.

General Provisions

1. Buildings are reviewed for compliance with fire safety regulations during the building permit procedure.

2. Buildings, installations, and facilities that, due to their nature, intended use, or other circumstances, pose a particular risk to persons, animals, or property in the event of a fire, are subject to mandatory cantonal fire safety approval by the governmental council.

General Provisions

1. The approval of new building materials, construction elements, components, heating units, and technical installations in the field of fire protection is contingent upon an assessment of fire protection quality by a recognized testing body.

2. The Aargau Insurance Office may permit exceptions.

General Provisions

1. The Government Council may restrict the retail trade of pyrotechnic items intended for entertainment purposes to specific occasions, attach additional conditions, and prohibit the sale of certain fireworks.

Article: Organization

1. Fire Safety is under the Supervision of the Government Council.

Article: Organization

1. The municipal council oversees fire protection within the municipality's area, insofar as it is not subject to cantonal orders and inspections, and ensures the rectification of fire protection deficiencies within this scope.

2. Its specific duties include

a) issuing fire protection measures for constructions under its fire police jurisdiction during the building permit procedures;

b) conducting acceptance inspections and periodic inspections to identify fire protection deficiencies as needed.

3. The municipal council may engage experts (such as chimney sweeps, building specialists, etc.) to fulfill its duties in the field of fire protection.

4. The municipal council supports the cantonal fire protection authority in fulfilling its responsibilities, particularly by reporting structures, facilities, and installations that require a cantonal fire protection permit.

Article: Organization

1. The Aargau Building Insurance ensures fire protection within the cantonal area, notably through

a) Monitoring the enforcement of fire protection regulations and issuing the necessary directives,

b) Issuing fire protection permits falling under its jurisdiction,

c) Conducting acceptance inspections and periodic inspections of buildings, facilities, and installations subject to its permit requirement as needed; in justified cases, experts may be consulted,

d) Conducting training and further education courses for cantonal and municipal fire protection authorities,

e) Advising authorities and individuals on fire protection issues and educating the public about fire prevention.

2. The administrative costs are borne by the Aargau Building Insurance, which receives the fees collected pursuant to § 24 paragraph 2.

Article: Organization

1. The department responsible for population and civil protection may impose a cantonal or regional fire ban in the event of extraordinary dryness.

2. The ban is issued upon the request of the Cantonal Leadership Staff (CLS).

Article: Organization

1. Municipalities may impose stricter fire bans for their municipal area than those issued by the cantonal authority.

2. If the canton does not issue a fire ban, municipalities may implement a local fire ban.

Article: Organization

1. The government council may delegate certain fire protection tasks to recognized professional organizations or suitable private enterprises, provided that the nature of the task permits it and significant substantive or organizational advantages are expected. The government council shall ensure legal protection.

Fire Safety Inspections

1. Inspections shall be conducted, as far as possible, in the presence of the owner or possessor of the building or facility.

2. Access shall be granted to the inspection authorities, insofar as it is necessary for the fulfillment of their duties. The necessary information shall be provided to them truthfully.

3. Observations made during the inspections are subject to official secrecy.

Fire Safety Inspections

1. A reasonable period must be granted for the rectification of fire protection deficiencies.

2. In the event of acute danger of fire or explosion, necessary immediate measures must be ordered.

3. If the follow-up inspection reveals that the deficiencies have not been rectified, the necessary enforcement measures must be taken in accordance with the provisions of the Administrative Procedure Act.

Heating Systems

1. The maintenance of heating installations is the responsibility of the owners.

2. They are required to have their installations safety-maintained by a registered professional at appropriate intervals and to rectify any identified deficiencies.

3. They must be able to document the safety maintenance as well as the rectification of any deficiencies, if applicable.

Heating Systems

1. Safety maintenance must be carried out professionally according to the technical standards and fire protection regulations. It consists of

a) the inspection of the combustion system and its installation area,

b) the necessary cleaning of the system, if required.

2. The specialist must inform the owners in writing of any defects that threaten the safe operation of the combustion system, unless the defects are rectified immediately with their consent. If necessary, the specialist sets a reasonable deadline for the correction of the defects.

3. The specialist reports significant defects to the competent fire protection authority. The authority conducts a follow-up inspection.

Firing Installations

1. Authorized to independently perform the safety maintenance of combustion systems is anyone who

a) possesses at least the qualifications of a chimney sweep forewoman or foreman with a federal professional certificate or an equivalent qualification, and

b) is registered in the public list of specialists maintained by the Aargau Building Insurance.

2. In the case of serious or repeated breach of duty, the Aargau Building Insurance may delete the entry in the list with immediate effect.

Firing Installations

1. The specialist may delegate tasks to employees for which their presence or involvement is not required.

Fees

1. The municipality may charge fees for processing applications for the granting of permits and exercising control and enforcement functions in accordance with this law.

2. The Aargau Building Insurance issues a fee schedule for the activities it undertakes based on this law, within the framework of the Fee Decree (FeeD) of September 19, 2023. It may waive the collection of fees in whole or in part.

10. Legal Protection Legal protection refers to the safeguarding of individuals' rights under the law. It encompasses various mechanisms and procedures designed to enforce and secure the legal rights and remedies available to individuals. This includes access to the courts, fair trial procedures, and remedies such as injunctions, damages, or specific performance. Legal protection ensures that individuals can seek redress for violations of their legal rights through proper legal channels.

1. Appeals against decisions of the municipal council regarding fire protection can be lodged with the Aargau Building Insurance within 30 days from the date of notification. Appeals against fire police decisions within the framework of the building permit procedure are governed by the Building Act.

2. Decisions and orders of the Aargau Building Insurance can be challenged before the Government Council within the same period.

3. In other respects, the procedure is governed by the provisions of the Administrative Procedure Act.

Criminal Provisions

1. Whoever intentionally or negligently contravenes this law or the promulgated implementing provisions, orders, and decisions based on it, shall be punished with a fine of up to CHF 10,000, unless federal penal provisions apply.

2. The modification is carried out by the ordinary criminal authorities responsible for offenses in the procedure applicable thereto.

3. Otherwise, the provisions of the Swiss Penal Code concerning offenses shall apply.

Transitional and Final Provisions

1. Existing buildings, structures, and facilities that do not comply with the new provisions at the time this law comes into effect shall be tolerated in their current state, provided they do not pose an immediate danger to persons, animals, or property.

2. If existing buildings, structures, or facilities are substantially altered or put to a different use, they must be brought into compliance with the new provisions.

Transitional and Final Provisions

1. By this law, Sections 61-64 of the Act on Building and Movable Property Insurance of January 15, 1934, are repealed.

Transitional and Final Provisions

1. This law shall be enacted by the government council upon approval by the people. It shall be published in the official legal collection.